COMPONENT IDENTIFICATION ENGINE SWITCH RECOIL STARTER GRIP I \ OIL DRAIN PLUG ENGINE SERIAL NUMBER 8
FUEL TANK CAP FUEL METER PLUG Record the engine and frame serial numbers for your future reference. Refer to these serial numbers wh
Engine Switch To start and stop the engine. Key position: OFF: To Stop the engine. ON: To run the engine. I I I ENGINE SWITCH Recoil
Fuel Valve The fuel valve is located between the fuel tank and carburetor. When the valve lever is in the ON position, fuel is a
Circuit Breaker The circuit breaker will automatically switch OFF if there is a short circuit or a significant overload of the genera
Oil Alert System The Oil Alert system is designed to prevent engine damage caused by an insufficient amount of oil in the crankcas
Ground Fault Circuit Interrupter (GFCI) Receptacle m Using the generator in rain, snow or near water can lead to death from electric
INSPECTION Perform the tests below to ensure proper operation of the GFCI. Record your test on the GFCI test card provided on the
5. Press the RESET BUTTON -The RESET BUTTON should be flush with the base. -If the RESET BUTTON is not flush with the TEST BUTTON,
GENERATOR USE Connections to a Building’s Electrical System Connections for standby power to a building’s electrical system must be mad
The generator is a potential source of electrical shock if misused. Do not expose the generator to moisture, rain or snow. Do not
AC Applications Before connecting an appliance or power cord to the generator: l Make sure that it is in good working order. Faulty
AC Operation 1. Start the engine (see page 25 1. 2. Switch ON the AC circuit breaker. 3. Plug in the appliance. Most motorized applia
l High Altitude Operation At high altitude, the standard carburetor air-fuel mixture will be too rich. Performance will decrease, and
Engine Oil pi6E-j Engine oil is a major factor affecting engine performance and service life. Non-detergent and 2-stroke engine oils
Fuel Recommendation 1. Check the fuel level gauge. 2. Refill the tank if the fuel level is low. Do not fill above the shoulder of t
Occasionally you may hear light “spark knock” or “pinging” (metallic rapping noise) while operating under heavy loads. This IS no cau
Oxygenated Fuels Some conventional gasolines are being blended with alcohol or an ether compound. These gasolines are collectively ref
STARTING THE ENGINE/STOPPING THE ENGINE Starting the engine 1. Make sure that the AC circuit breaker is in the OFF position. The gen
MAINTENANCE The Importance of Maintenance Good maintenance is essential for safe, economical, and trouble-free operation. It will also h
Maintenance Safety Some of the most important safety precautions follow. However, we cannot warn you of every conceivable hazard that
Thank you for purchasing a Honda generator. We want to help you to pperate it safely. -P et the best results from your new generator
Emission Control System Source of Emissions The combustion process produces carbon monoxide, oxides of nitrogen, and hydrocarbons. Contr
Problems That May Affect Emissions If you are aware of any of the following symptoms, have your engine inspected and repaired by yo
Replacement Parts The emission control systems on your Honda engine were designed, built, and certified to conform with EPA and Cali
Maintenance Schedule at every indicated month g hour interval,whichever NOTE: l Emission related items. (1)Service more frequently when us
Engine Oil Change Drain the oil while the engine is warm to assure rapid and complete draining. I. Remove the drain plug and seali
Air Cleaner Service A dirty air cleaner will restrict air flow to the carburetor. To prevent carburetor malfunction, service the air
Fuel Sediment Cup Cleaning The sediment cup prevents dirt or water which may be in the fuel tank from entering the carburetor. If
In order to service the spark plug, you will need a spark plug wrench (commercially available). Recommended spark plugs: BPRGES (NGK)
6.Check that the spark plug washer is in good condition, and thread the spark plug in by hand to prevent cross-threading. 7.After
Spark Arrester Maintenance If the generator has been running, the muffler will be very hot. Allow it to cool before proceeding. I The
CONTENTS SAFETY ... 4 Safety Label Locations ...
3. Use a brush to remove carbon deposits from the spark arrester screen. Inspect the spark arrester screen for holes or tears. Repl
When transporting the generator, turn the engine switch and the fuel valve OFF. Keep the generator level to prevent fuel spillage.
1.Drain the carburetor by loosening the drain screw. Drain the gasoline into a suitable container. Gasoline is extremely flammable and
TROUBLESHOOTING When the engine will not start: Is there fuel in the NO p Refill the fuel tank. tank? YES 7 Is there enough oil NO in
No electricity at the AC receptacles: Is the AC circuit breaker NO ~ Turn the AC circuit breaker ON? ON. Is the GFCI in the reset p
WIRING DIAGRAM I AC RECEPTACLES-- GENERATOR BLOCK - -- 43
SPECIFICATIONS Dimensions Model EB2500X Power product description code EZCP Length 505 mm (19.9 in) Width 420 mm (16.5 in) Height 420 mm (1
Honda power equipment dealership personnel are trained professionals. They should be able to answer any question you may have. If yo
INDEX COMPONENT IDENTIFICATION ... 8 CONTROLS ...
MEMO 47
TRANSPORTING/STORAGE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ..*... 39 TROUBLE
MEMO 48
SAFETY SAFETY LABEL LOCATION These labels warn you of potential hazards that can cause serious injury. Read them carefully. If a label
[I EL )2500x HONDA MOTOR CO.,LTD. MADE IN JAPAN @ n BE S WITH RE BEFORE FOR DE- SEE THE OCCUPANT’STEST RECORD 5
SAFETY INFORMATION Honda generators are designed to give safe and dependable service if operated according to instructions. Read and
Fire and Burn Hazards l The exhaust system gets hot enough to ignite some materials. -Keep the generator at least 1 meter (3 feet)